Indirect Fired Heater Manufacturer
Indirect Fired Heater HPL 600DJ Herman Nelson

Temporary Construction Heater

Certified by O-TL to UL 733-1993 (To CSA Standards)

This Indirect Fired Heater is designed to operate in freezing weather down to -40 °F/°C and below. This indirect fired heater has a heat rise of 350 °F (177 °C) which means that if the ambient temperature is at -40 °F, the heat outlet will still be 250°F. Powered by a Honda 5.5 HP Gasoline driven engine, this Herman Nelson indirect heater is the best in the industry and used by both the US and Canadian military and most major airlines worldwide. The BT400NEX-G indirect fired heater is manufactured in Canada and built to withstands the brutal Canadian winters. This heater has been in continuous production with ongoing technological improvements since 1973. In 2010 the original Herman Nelson was upgraded to full electronic temperature control and valves. Easier to operate, more reliable and economical to maintain. Certified by O-TL to UL 733-1993 (TO CSA STANDARDS)

HEATER SPECIFICATIONS

Heating Capacity 588,000 BTU/h
Maximum Air Delivery Rate 5,500 CFM (Optionals 6,500 CFM)
Max Output Temp 200°F (93.3 °C)
Fuel Capacity 90 U.S Gallons (341 L) with Containment Pan
Fuel Type Diesel No. 7 or No. 2 Kerosene Furnace Oil
Maximum Fuel Consumption 4.2 GPH @ Full Output
Nozzle 2.75 GPH (175 psi)
Static Pressure 3.0" w.c (Optional 3.6" w.c)
Fan Motor 1HP
Ignition Electric
Ductability 150 ft Discharge - 50 ft Inlet
Burner Beckett CF800
Engine Kubota Z482 Tier 4F in MQ 7000 7 kW Generator - Electric Start
Outlet Duct 2 x 12" or 1 x 16" Diameter Outlet Plus 2 x 12" or 1 x 16" Inlet
Run Time 19 Hours at 100% Load (connection to external fuel cell available)
Electrical 120 - 240 VAC / 1PH / 6 kW
Air Flow 5,500 CFM
Temp Rise 220 °F
Hitch Setup 2 5/16” Ball Hitch or Pintle
Weight (dry with trailer) 2,600 lb
Dimensions 135" L x 95" W x 108" H

OPTIONS

Indirect Diesel Heater

Overview Video

The onboard construction heater is a BT Blaze 600D Turbo, which has a temperature range of 150°F (65.56°C) – 250°F (121.11°C). This temporary construction heater delivers 588,000 BTU’s of hot clean air at volumes of 5500 CFM and capable of 4″ of static pressure. The indirect fired heater has air recirculation capabilities that allow the unit to discharge hot air up to 150ft from the location where the heat is required and can recirculate air up to 50ft.

L.E.D Light Tower

Overview Video

The onboard construction heater is a BT Blaze 600D Turbo, which has a temperature range of 150°F (65.56°C) – 250°F (121.11°C). This temporary construction heater delivers 588,000 BTU’s of hot clean air at volumes of 5500 CFM and capable of 4″ of static pressure. The indirect fired heater has air recirculation capabilities that allow the unit to discharge hot air up to 150ft from the location where the heat is required and can recirculate air up to 50ft.

Stand-Alone Generator

Overview Video

Additionally, placed within this temporary heater is a dependable and efficient job site power generator, the MQ Power 7000. This generator built into the HPL 600 D7 delivers reliable power in a compact sound attenuated package.

The size of this generator makes it ideal for construction, standby or industrial applications.

Some noteworthy features include the AC Output 7kW maximum, 6kW continuous. An hour meter to track the usage and maintenance intervals accurately. A dependable Tier 4 Final Kubota Diesel engine and full-panel GFCI protection compliant with OSHA and NEC regulations. Lastly, this generator has a full power switch, which provides the operator with a balanced output under changing loads.

Accessories for this heater

FREQUENTLY ASKED QUESTIONS

The BT400 NEX SERIES is best suited for applications requiring a indirect fired heater that can operate in the most severe conditions in remote locations that do not have any power available or it is difficult to obtain. Best suited to applications requiring thermostatically controlled quick clean air heat such as aircraft engine & cabin pre-heating, remote industrial sites, oil & gas sites and military requirements.

EXECUTIVE SUMMARY

Indirect Fired Heater Manufacturer

Thanks for Visiting Aerotech Herman Nelson!

Would you help us improve our website by filling out a quick survey?

2024 - 2025 Holiday Business Hours

Happy holidays

DECEMBER 24
[Open 8:00am – 12:00pm CDT]
DECEMBER 25
[CLOSED]
DECEMBER 26
[CLOSED]
DECEMBER 27
[OPEN 8:00AM – 4:30PM CDT]
DECEMBER 31
[OPEN 8:00AM – 4:30PM CDT]
JANUARY 1
[CLOSED]
JANUARY 2
[Back To Regular Hours]

Regular Business Hours
MONDAY – FRIDAY 8:00AM – 4:30PM CDT

DECEMBER 24 [Open 8:00am – 12:00pm CDT]
DECEMBER 25 [CLOSED]
DECEMBER 26 [CLOSED]
DECEMBER 27 [OPEN 8:00AM – 4:30PM CDT]
DECEMBER 31 [OPEN 8:00AM – 4:30PM CDT]
JANUARY 1 [CLOSED]
JANUARY 2 [Back To Regular Hours]

Regular Business Hours
MONDAY – FRIDAY 8:00AM – 4:30PM CDT

we look forward to seeing you in the new year!