In order to properly create a quote, it is necessary for you fill in the (*Required fields) found in the form below. This information helps us to organize and communicate with you effectively.
We respect your privacy and therefore will never use, sell, share or distribute the collected information you provide us here with a third-party. This information is solely for our usage to create your quote within our systems
We will respond to you within 24 hours or the next business day.
If you require immediate assistance, please call 1 (800) 486-4328.
(* Required fields)
This Indirect Fired Heater is designed to operate in freezing weather down to -40 °F/°C and below. This indirect fired heater has a heat rise of 350 °F (177 °C) which means that if the ambient temperature is at -40 °F, the heat outlet will still be 250°F. Powered by a Honda 5.5 HP Gasoline driven engine, this Herman Nelson indirect heater is the best in the industry and used by both the US and Canadian military and most major airlines worldwide. The BT400NEX-G indirect fired heater is manufactured in Canada and built to withstands the brutal Canadian winters. This heater has been in continuous production with ongoing technological improvements since 1973. In 2010 the original Herman Nelson was upgraded to full electronic temperature control and valves. Easier to operate, more reliable and economical to maintain. Certified by O-TL to UL 733-1993 (TO CSA STANDARDS)
Heating Capacity | 588,000 BTU/h |
Maximum Air Delivery Rate | 5,500 CFM (Optionals 6,500 CFM) |
Max Output Temp | 200°F (93.3 °C) |
Fuel Capacity | 90 U.S Gallons (341 L) with Containment Pan |
Fuel Type | Diesel No. 7 or No. 2 Kerosene Furnace Oil |
Maximum Fuel Consumption | 4.2 GPH @ Full Output |
Nozzle | 2.75 GPH (175 psi) |
Static Pressure | 3.0" w.c (Optional 3.6" w.c) |
Fan Motor | 1HP |
Ignition | Electric |
Ductability | 150 ft Discharge - 50 ft Inlet |
Burner | Beckett CF800 |
Engine | Kubota Z482 Tier 4F in MQ 7000 7 kW Generator - Electric Start |
Outlet Duct | 2 x 12" or 1 x 16" Diameter Outlet Plus 2 x 12" or 1 x 16" Inlet |
Run Time | 19 Hours at 100% Load (connection to external fuel cell available) |
Electrical | 120 - 240 VAC / 1PH / 6 kW |
Air Flow | 5,500 CFM |
Temp Rise | 220 °F |
Hitch Setup | 2 5/16” Ball Hitch or Pintle |
Weight (dry with trailer) | 2,600 lb |
Dimensions | 135" L x 95" W x 108" H |
Overview Video
The onboard construction heater is a BT Blaze 600D Turbo, which has a temperature range of 150°F (65.56°C) – 250°F (121.11°C). This temporary construction heater delivers 588,000 BTU’s of hot clean air at volumes of 5500 CFM and capable of 4″ of static pressure. The indirect fired heater has air recirculation capabilities that allow the unit to discharge hot air up to 150ft from the location where the heat is required and can recirculate air up to 50ft.
Overview Video
The onboard construction heater is a BT Blaze 600D Turbo, which has a temperature range of 150°F (65.56°C) – 250°F (121.11°C). This temporary construction heater delivers 588,000 BTU’s of hot clean air at volumes of 5500 CFM and capable of 4″ of static pressure. The indirect fired heater has air recirculation capabilities that allow the unit to discharge hot air up to 150ft from the location where the heat is required and can recirculate air up to 50ft.
Overview Video
Additionally, placed within this temporary heater is a dependable and efficient job site power generator, the MQ Power 7000. This generator built into the HPL 600 D7 delivers reliable power in a compact sound attenuated package.
The size of this generator makes it ideal for construction, standby or industrial applications.
Some noteworthy features include the AC Output 7kW maximum, 6kW continuous. An hour meter to track the usage and maintenance intervals accurately. A dependable Tier 4 Final Kubota Diesel engine and full-panel GFCI protection compliant with OSHA and NEC regulations. Lastly, this generator has a full power switch, which provides the operator with a balanced output under changing loads.
The BT400 NEX SERIES is best suited for applications requiring a indirect fired heater that can operate in the most severe conditions in remote locations that do not have any power available or it is difficult to obtain. Best suited to applications requiring thermostatically controlled quick clean air heat such as aircraft engine & cabin pre-heating, remote industrial sites, oil & gas sites and military requirements.
Would you help us improve our website by filling out a quick survey?
DECEMBER 24
[Open 8:00am – 12:00pm CDT]
DECEMBER 25
[CLOSED]
DECEMBER 26
[CLOSED]
DECEMBER 27
[OPEN 8:00AM – 4:30PM CDT]
DECEMBER 31
[OPEN 8:00AM – 4:30PM CDT]
JANUARY 1
[CLOSED]
JANUARY 2
[Back To Regular Hours]
Regular Business Hours
MONDAY – FRIDAY 8:00AM – 4:30PM CDT
DECEMBER 24 [Open 8:00am – 12:00pm CDT]
DECEMBER 25 [CLOSED]
DECEMBER 26 [CLOSED]
DECEMBER 27 [OPEN 8:00AM – 4:30PM CDT]
DECEMBER 31 [OPEN 8:00AM – 4:30PM CDT]
JANUARY 1 [CLOSED]
JANUARY 2 [Back To Regular Hours]
Regular Business Hours
MONDAY – FRIDAY 8:00AM – 4:30PM CDT
we look forward to seeing you in the new year!